TX-LP-2100H/2100HW Intelligent Infusion Pump with Heater

Introduction

Intelligent Infusion Pump with Heater
Intelligent Infusion Pump with Heater

1. LCD color display, vivid and intelligent.

2. Build-in warming module to preheat medicine fluid, softening infusion line and prevent hypothermia (low temperature) during infusion.

3. Unique semi-extrusion technique, good for all kinds of fluid transfusion, including medical solution, blood, plasma and also nutritional liquid.

4. New industrial design, making this unit lighter weighted (only 1.3kg), more compact, achieving a real handheld machine.

5. Available with optional Wi-Fi supervision function. With Wi-Fi receiver module installed on computer, up to 60 units of pump could be monitored real-timely.

6. Safer bottom-hinged swinging door to avoid any core-part damage caused by possible liquid leakage.



Functions and Parameters

1

Pump type

 Finger-type peristaltic pump

2Applicable infusion sets Special or quality PVC,TPE infusion sets with an external diameter of 3.4mm~4.5mm.
3Infusion mode  Flow-rate mode, time mode, drip-rate mode, body-weight mode.
4

Flow-rate mode

 Flow-rate setting: Between (1.0~1200.0)ml/h or (1.0~1200.0)ml/h (calculation result) at 0.1ml/h per step

5

Preset time mode

 Preset time setting: Set between (1s~99h59m59s) at 1s per step.

6

Drip-rate mode

 Drip-rate setting: Set between 1~333d/min  at 1d/min per step.

7Body-weight mode

 Body-weight setting: Set between (1~300)kg at 1kg per step.

 Mg dosage setting  : Set between (0.01~999.99)mg/kg/h at  0.01mg/kg/h per step

 Infusion dose setting : Set between (0.1~9999.9)mg at 0.1mg per step

8

Flow-rate setting for KVO function

 Set between (1.0~5.0)ml/h at 0.1ml/h per step.

9Alarm

 1.Air in tube, graded sensitivity adjustable

 2.Bubble sensor fault

 3.1.Upper-end occlusion,-20~-60kPa, graded sensitivity adjustable

 3.2.Upper-end base-pressure fault(pressure sensor broken)

 4.1.Lower-end occlusion, -20~-60kPa, graded sensitivity adjustable

 4.2.Lower-end base-pressure fault(pressure sensor broken)

 5.1.Pump rotation fault

 5.2.Inverse-infusion

 6.Abnormal door-opening

 7.Low battery power, battery fault

 8.Overtime pause

 9.Completed infusion

 10.AC power fault

 11. Double bubble alarm

 12.MCU fault and stop infusion

10Data storage

 Memory calculation: Auto-record infusion set data for late usage

 Setting record: Auto-record last infusion setting for late usage

 History(SOE): up to 1000 latest infusion events can be recorded(start time, end time, flow-rate, stop reason and the like)
11

Safety classification

 Class I, CF device,IPX4

12

Power supply

 AC power:100-240V,50/60Hz,built in rechargeable NI-MH battery 

 Power consumption: ≤20VA
13

Shape and weight

 W100×H134×D80mm; ±5mm, Net weight≤1.3kg
14Heating function Built-in heating module
 Built-in heating function
 Optional external heating belt.
15Wifi module Built-in wireless data transmitter
 Wireless networking(optional signal receiver installed on computer)
16Screen LCD color screen, resolution:320×240
17Special function Alarm stops when occlusion disappears
                  4. 5. 6. 7 :  Preset volume setting: Between (0.1~9999.9)ml at 0.1ml per step 

                  Display of accumulated volume : (0~9999.9)ml, “zero clearing” only and modification is unavailable