1. LCD color display, vivid and intelligent.
2. Build-in warming module to preheat medicine fluid, softening infusion line and prevent hypothermia (low temperature) during infusion.
3. Unique semi-extrusion technique, good for all kinds of fluid transfusion, including medical solution, blood, plasma and also nutritional liquid.
4. New industrial design, making this unit lighter weighted (only 1.3kg), more compact, achieving a real handheld machine.
5. Available with optional Wi-Fi supervision function. With Wi-Fi receiver module installed on computer, up to 60 units of pump could be monitored real-timely.
6. Safer bottom-hinged swinging door to avoid any core-part damage caused by possible liquid leakage.
Functions and Parameters
1 | Pump type | Finger-type peristaltic pump |
2 | Applicable infusion sets | Special or quality PVC,TPE infusion sets with an external diameter of 3.4mm~4.5mm. |
3 | Infusion mode | Flow-rate mode, time mode, drip-rate mode, body-weight mode. |
4 | Flow-rate mode | Flow-rate setting: Between (1.0~1200.0)ml/h or (1.0~1200.0)ml/h (calculation result) at 0.1ml/h per step |
5 | Preset time mode | Preset time setting: Set between (1s~99h59m59s) at 1s per step. |
6 | Drip-rate mode | Drip-rate setting: Set between 1~333d/min at 1d/min per step. |
7 | Body-weight mode | Body-weight setting: Set between (1~300)kg at 1kg per step. |
Mg dosage setting : Set between (0.01~999.99)mg/kg/h at 0.01mg/kg/h per step | ||
Infusion dose setting : Set between (0.1~9999.9)mg at 0.1mg per step | ||
8 | Flow-rate setting for KVO function | Set between (1.0~5.0)ml/h at 0.1ml/h per step. |
9 | Alarm | 1.Air in tube, graded sensitivity adjustable |
2.Bubble sensor fault | ||
3.1.Upper-end occlusion,-20~-60kPa, graded sensitivity adjustable | ||
3.2.Upper-end base-pressure fault(pressure sensor broken) | ||
4.1.Lower-end occlusion, -20~-60kPa, graded sensitivity adjustable | ||
4.2.Lower-end base-pressure fault(pressure sensor broken) | ||
5.1.Pump rotation fault | ||
5.2.Inverse-infusion | ||
6.Abnormal door-opening | ||
7.Low battery power, battery fault | ||
8.Overtime pause | ||
9.Completed infusion | ||
10.AC power fault | ||
11. Double bubble alarm | ||
12.MCU fault and stop infusion | ||
10 | Data storage | Memory calculation: Auto-record infusion set data for late usage |
Setting record: Auto-record last infusion setting for late usage | ||
History(SOE): up to 1000 latest infusion events can be recorded(start time, end time, flow-rate, stop reason and the like) | ||
11 | Safety classification | Class I, CF device,IPX4 |
12 | Power supply | AC power:100-240V,50/60Hz,built in rechargeable NI-MH battery |
Power consumption: ≤20VA | ||
13 | Shape and weight | W100×H134×D80mm; ±5mm, Net weight≤1.3kg |
14 | Heating function | Built-in heating module |
Built-in heating function | ||
Optional external heating belt. | ||
15 | Wifi module | Built-in wireless data transmitter |
Wireless networking(optional signal receiver installed on computer) | ||
16 | Screen | LCD color screen, resolution:320×240 |
17 | Special function | Alarm stops when occlusion disappears |
4. 5. 6. 7 : Preset volume setting: Between (0.1~9999.9)ml at 0.1ml per step Display of accumulated volume : (0~9999.9)ml, “zero clearing” only and modification is unavailable |